Central Systems

Tank, Pump, Power, and Control

LubeCon's central systems utilize heavy duty pump & motor combinations for reliability and performance.

Each central system can feed multiple lubrication units while allowing the customer to monitor low level, power and pressure faults.

Fully automated operation takes the worry out of chain lubrication schedules and ensures your chain is lubricated on time, every time.

Central systems come in 55- and 12-gallon tank sizes to fit your specific needs. All central systems are available with either a power supply to feed multiple lubrication units or an ASC controller.

Overview:

CENTRAL SYSTEM (STANDARD)

  • 1/3hp 120VAC or 220VAC TEFC industrial motor with thermal overload and automatic reset protection ensures a long maintenance-free motor life.
  • Multiple tank and controller configurations allow you to select the right central system for your application.
  • Standard central systems can pump lubricant viscosity up to 100 SUS.

CENTRAL SYSTEM (HEAVY LUBE)

  • 1/3hp 120VAC or 220VAC TEFC industrial motor with thermal overload and automatic reset protection ensures a long maintenance-free motor life.
  • Multiple tank and controller configurations allow you to select the right central system for your application.
  • Heavy lube central systems can pump lubricant viscosity’s up to 1000 SUS.

LIGHT DUTY CENTRAL SYSTEM (SLU)

  • 1/7hp 120VAC TEFC industrial motor with thermal overload and automatic reset protection ensures a long maintenance-free motor life.
  • SLU is specifically designed for single-line lubrication using dry film lubricants. (SLU central systems should only feed one lubricator)

Features:

CENTRAL SYSTEM (STANDARD & HEAVY LUBE)

  • Easy to read top-mounted dial level gauge (55 gallons only). Side mount level gauge standard on all 12-gallon systems.
  • Thermal overload protection and short circuitry protection.
  • Low-level sensor with automatic pump shutdown.
  • Easy to see power, pump, low level, and pressure fault output lights.
  • PLC monitoring for power, pump, and system faults
  • System reset and test buttons.
  • 50 Micron inline filtration with backflow check valve
  • Large mouth fill cap.

LIGHT DUTY CENTRAL SYSTEM (SLU)

  • Easy to read side-mounted tank level gauge.
  • Thermal overload protection and short circuitry protection.
  • Low level sensor with automatic pump shutdown.
  • Inline filtration with a backflow check valve.
  • Large mouth fill cap.

Specifications:

CENTRAL SYSTEM (STANDARD)

  • 120VAC @ 15 amp or 220VAC @ 10amp dedicated circuit
  • 1/3HP 60Hz motor with thermal overload protection
  • 1/2GPM industrial gear pump
  • 55 Gal. or 12 Gal. reservoirs
  • Pumping capabilities up to 100 SUS at 200 PSI

CENTRAL SYSTEM (HEAVY LUBE)

  • 120VAC @ 15 amp or 220VAC @ 10amp dedicated circuit
  • 1/3HP 60Hz motor with thermal overload protection
  • 1/2GPM industrial gear pump
  • 55 Gal. or 12 Gal. reservoirs
  • Pumping capabilities up to 100 SUS at 200 PSI

LIGHT DUTY CENTRAL SYSTEM (SLU)

  • 120VAC @ 15 amp dedicated circuit
  • 1/7HP 60Hz motor with thermal overload protection
  • 12 Gal. reservoir
  • Pumping capabilities (dry film lubricants)

Accessories:

CENTRAL SYSTEM (STANDARD & HEAVY LUBE)

  • PLC Interface for power, pump, and system faults
  • High pressure and low-pressure fault switch
  • 120VAC and 220VAC versions available
  • Auto refill capable
  • Available filtration options
  • Washdown Central Systems is available